One of the most familiar faults with an aging heating system is a radiator that is hot at the top and cold at the bottom and it doesn't usually work itself out. Usually, the cause is that silt builds up at the bottom of the radiator, blocking the flow of water and leaving the lower half unheated.This article explains why this occurs, what you can check yourself and what your heating engineer will do to resolve the issue. Early diagnosis will prevent the rest of the system becoming compromised and is a common reason for booking a yearly boiler service Bristol households a popular choice. The sections below look at causes, simple tests and the options which range from cleaning to replacing a radiator.
Hot water enters a radiator at the top and travels down so a healthy radiator will be hot all over. If the bottom third remains cold and the top is hot, the water can't circulate because something is blocking the flow; more often than not, it's sludge, a black, fine powder of rust and iron-oxide that accumulates in the lowest part of the radiator, where the flow is slowest.
This is an entirely different pattern to cold at the top and hot at the bottom, which indicates trapped air and is cured with a bleed. It's worth differentiating the two, since bleeding a radiator full of sludge is wasted effort. Press the palm of your hand along the bottom edge after the system has had twenty minutes to heat through, and see if the cold patch remains in roughly the same place.
An infrared thermometer (available to borrow when an engineer turns up) reveals the cold edge as a band of lower temperature across the base, and the same patch can be visible in a batch of radiators, typically those near the furthest point in the system from the boiler.
Hot top cold bottom air or sludge. Cold top hot bottom air. Thats all the words mean. Its which is hot and which is cold that dictates whether you need a bleed key or an engineer.
It takes time for sludge to form. Water trapped inside steel radiators and old iron pipework rusts from the inside when the oxygen enters, and the debris it produces remains suspended in the circuit until it deposits. The system inhibitor used to prevent this occurring over the years is gradually used up, especially if the system has been drained and refilled several times to effect repairs or extensions.
Bristol homes built between the Victorian era and the present day include everything from original pipework to 1990s extensions which linked newer radiators to existing runs, and this combination of different metals exacerbates corrosion.
Narrow bore pipework in houses built since the 1970s produces problems by restricting the flow of debris, which has less room to pass through, and the evidence can be found in the water you collect when bleeding a radiator: black or brown water is a warning that the inhibitor has stopped working and the debris is already circulating. Early boiler repairs Bristol homeowners have for their heating system cost a lot less than waiting until none of the radiators get hot any more.
Collect a small amount of bled water in a white cup. Clear water indicates condition is good, if water is dark or cloudy it is time to wash your system.
Start with the simplest of checks. Make sure the two valves which switch flow through the radiator are fully open: a thermostatic head can seize, switching the flow off but the pin inside the top can be pushed out with a finger once the head is removed. Switch the heating on and feel each pipe that enters and leaves the radiator: it should be hot as it enters and only slightly cooler as it leaves.
Now compare your suspect radiator to its neighbour. If just a single one is cold, you probably have local restrictions of flow. If you identify a number of cold patches in the house, however, the resulting sludge will be circulating through the whole system. Bleed the radiator (if you have to, so be it this often clears the stubborn ones), then check the boiler pressure topped up if necessary. If the cold patch reappears after a day or two, the problem is caused by a dirty ingredient in the water which, in the end, will have to be sorted out by calling in an engineer to flush the system rather than replacing parts.
Check your pump by listening to it: it should emit a gentle hum, and you can feel the vibrations by the boiler where the pipework leaves it. If it is silent and not pumping heat through the radiators then this is a different issue to the previous one turning the room thermostat up will not make the radiator warm any faster, just put the boiler to work more.
Don't never force a valve spindle if it feels tight or if it will not turn. Excessive force can break the valve or break the spindle making what should be a quick check into a leak or a much more costly repair. If a valve will not move easy, then it is better to stop and get a heating engineer to take a look.
The heating engineer starts by testing the water and checking the temperature of each radiator, which will normally be done with a thermal reading so he can see exactly where the flow stops. An amount of light contamination can be removed with a cleaning agent in the system for a time before being drained off and refilled.
Heavier contamination requires the radiators to be cleaned individually, or the system to be pumped out using a pump which blows the water through at speed, when the water is turned clear he adds fresh inhibitor which prevents the rusting of the metal, and then balances the radiators so that the heat output is shared between rooms. The iron particles are also captured by a magnetic filter in the boiler return, preventing them from returning to the boiler and from causing damage over time.
Years of contaminant in the water can damage the boiler too, and a new Bristol boiler would have its guarantee compromised by fitting it to unflushed pipework! On larger properties the engineer will usually flush one floor at a time so heating is not off longer than necessary and will leave a final check to record the flow and return temperature that the water circuit is unblocked.
Empty once a year to keep your heating system clean and working effectively. Dirt, rust and debris could gather in the cup (shown) seen as the black substance that would continually flow through your boiler, pipes and radiators and impact on your heating and the long-term efficiency of your system. Emptying and cleaning regularly will ensure cleaner water and your system can run smoothly.
It's not always possible to wait. If a radiator is excessively scaled or rusted through on the bottom or leaking at the joins, it may need replacing, and an out of date boiler working against a years of constriction may also have reached the end of its lifespan. A heating engineer will be honest about whether it would be worth doing it all at once or should only be partial or full replacement, and will put all of the options alongside each other so you can make comparisons.
When the plan is to fit a new boiler, the job order includes a survey of the radiators, pipework and hot water cylinder, and any cleaning is built into the job so the one visit takes care of everything. Repairing or replacing a single radiator is simple when the rest are in good condition, and you get a new radiator in the size that is right for the room, with the same pair of valves replaced at the same time. Warranties of up to twelve years depend on the radiators being properly cleaned and then serviced regularly, so the documentation following each annual visit is important.
Heating which has been properly balanced, bled and thoroughly cleaned also reaches a higher temperature faster and finds a more comfortable steady heat, so you benefit in comfort along with in paper work. If the radiators were already going downhill, the first week or two with a fresh clean will be almost startling as the bottom will warm up again. We ensure the boiler is installed with a full flow boiler filter, that the old water is flushed out and the system filled with fresh inhibitor and that the manufacturer's guarantee is protected.
Hold on to the flushing certificate plus a copy of each year's report. They demonstrate the system has been maintained should the need for a warranty claim ever arise.
Conclusion
Warm on top, cold underneath is hardly ever an indication a radiator is broken. Typically sludge has built up in the slowest part of the system and bleeding will do nothing to resolve it. Checks with hand, inspection of the bled water and simple comparison of the different radiators will confirm the extent of the build up. A good flush, fresh inhibitor and a magnetic filter will leave the system clean and protected for years, records from the visits will back up any warranty claim. Fixing it now will keep the rooms warm, take the load off the boiler and prevent the heating from packing up in the depths of winter.